Cobalt Networks 8321(-C) ユーザーズマニュアル

ページ / 48
8310/8321 User Manual 
••••
 (V 1.0)
Page 29
seconds after the fan door is closed, then adjust to the appropriate level based on power
consumption.
 
Monitors the frame door and PS-8300(s) to ensure that fans in all units are operating
correctly.
 
Monitors the fan door and notifies the user if it is left open too long.
 
Monitors the status of other cards in the frame via the internal bus.
 
Generates alarms if any of the monitored functions develop errors.
Next you will learn the various controls and LEDs available on the MFC-8310 controller card.
Controls and LEDs for the Controller Card
This section provides information on the jumpers, buttons and LEDs for the MFC-8310 controller card.
The location of the LEDs and controls for fan, alarm, and communication activity are shown in the
following figure.
Alarm LED
Status OK LED
Comm Activity LED
Alarm Mute/Bootload Button
Alarm Config Jumper
Fan Board Connector Edge
Figure 12. MFC-8310  Card Edge Controls
MFC-8310 Alarm Configuration Jumper
The Alarm Configuration Jumper enables or disables the audio alarm signal. The Alarm LED will still
be lit if alarm conditions are occurring, but the audio will be off.
Alarm Mute Button
If the optional CFM-8310 Cooling Fan Module is installed, there is an Alarm Mute Button on the right
side of the frame door front. If a card, that is in the frame, is reporting an error, pressing the Alarm
Mute Button will mute the audio alarm until another fault condition occurs.
MFC-8310 LEDs
The front edge of the MFC-8310, and the CFM-8310 in the frame door, have LED indicators for
cooling module fan, alarm, and communication activity. The CFM-8310 provides LED and Alarm
switching controls to the front edge of the 8310 frame door.