Audible Alarm Trouble Shooting:
Problem
Cause
Solution
Sounding every 4 
seconds
The UPS is on battery 
Check the input voltage, 
the input fuse resp. the 
circuit breaker
The battery is running low
Save your work and turn 
off your equipment
Sounding every 
second
Output overload
Check load level indicator 
and remove some load
The UPS fails
Please contact your local 
dealer
Continuously 
sounding
Battery may need to 
charge or service
Charge or replace the 
battery
6.3
General Fault Diagnosis and Fault Rectification
Problem
Cause
Solution
The power cord is 
not connected 
correctly
Check the power cord 
connection, especially the fit 
of the plug in the socket of the 
UPS
The UPS is not on 
when power switch is 
pressed
The wall outlet may 
be faulty
Please contact your local 
qualified electrician 
The UPS output 
may short-circuit or 
overload
1. Disconnect all loads and 
restart UPS. Connect loads 
again one by one.
2. Ensure loads are not 
detective or shorted internally 
Internal fuse may be 
blown
Please contact your local 
dealer