Parker Products ViX500AE ユーザーズマニュアル

ページ / 136
VIX  AE SERVO DRIVE USER GUIDE
66
Connections
ViX X4
connector
Description
6K connectors
Description
1
Ana1+
3 - Drive
Command +
2
Ana1-
6 - Drive
Command -
3
0V
9 - Drive
Isolated Gnd
6
Fault
5 - Drive
Fault
9
A- out
3 - Encoder
A -
10
B- out
5 - Encoder
B -
11
Energise
7 - Drive
Shutdown (NO)
14
A+ out
2 - Encoder
A +
15
B+ out
4 - Encoder
B +
Table 4-8.  Velocity/Torque Mode Connections
*Pins 13 and 14 on the 6K DRIVE connector should be connected together.
The CNTRL-P terminal on the 6K should be connected to +24V DC.
Velocity Mode Commands
For the ViX drive issue the following commands:
1MV
;Mode Velocity
1W(ES,0)
;Energise input active level
1SV
;Save settings
A valid MOTOR command is required.
At least some feed-forward and velocity gain needs to be used to tune the PIVF loop, that is
GF=GV=5.0.
For the 6K4 issue the following commands:
AXSDEF1111
All axes are steppers
ERES8000,8000,8000,8000
Should match ViX motor resolution
DRFLVL1111
Drive fault active level
DRFEN1
Enable drive fault detection
LH0,0,0,0
Disable limits (optional)
TGAIN
Read all gains
SGP
Set proportional gain
SVG
Set velocity gain
A
V
D
GO1
Execute move