Troubleshooting the CSS Fans
The following sections discuss:
Troubleshooting the CSS 11501 Chassis Fans
The CSS 11501 has six fans. When the CSS starts up and the fans are operational, 
the following message appears:
CHMGR: All fans are present (6). 
Note
This message is displayed only if the logging level is set to the Info-6 or Debug-7 
level.
If a fan fails when the CSS 11501 starts up, or fails during its normal operation, 
the following message appears:
CHMGR: Missing fans. Expected 6. Found 
number
.
The number variable indicates the total number of functioning fans. If the 
CSS 11501 starts to overheat, the following message appears:
Temperature has reached x celsius for slot number
The variable indicates the temperature of the CSS 11501. 
When a fan failure occurs, obtain technical assistance.