Cisco Systems 11500 Series ユーザーズマニュアル

ページ / 184
Chapter 2      Cabling and Troubleshooting the CSS
Troubleshooting the CSS Hardware Components
2-50
Cisco 11500 Series Content Services Switch Hardware Installation Guide
78-13884-06
Troubleshooting the CSS 11506 Fan Module
The CSS 11506 has three fans in a single fan module. When the CSS starts up and 
fans are operational, the following message appears:
CHMGR: All fans are present (3). 
Note
This message is displayed only if the logging level is set to the Info-6 or Debug-7 
level.
If a fan fails when the CSS starts up, or fails during its normal operation, the 
following message appears:
CHMGR: Missing fans. Expected 3. Found 
number
.
The number variable indicates the total number of functioning fans. 
If the modules start to overheat in the chassis, the following message appears:
Temperature has reached 
x
 celsius for slot 
number
The x variable indicates the temperature of the module. The module in the 
designated slot number is running a temperature that is too high.
When a fan failure occurs, you must replace the fan module to prevent the CSS 
modules from overheating.