Philips BUK209-50Y ユーザーズマニュアル

ページ / 8
Philips Semiconductors
Product specification
 TOPFET high side switch
BUK214-50Y 
 SMD version of BUK209-50Y
 
INPUT CHARACTERISTICS
9 V 
 V
BG
 
 16 V.  Limits are at -40˚C 
 T
mb
 
 150˚C and typicals at T
mb
 = 25 ˚C unless otherwise stated.
SYMBOL
PARAMETER
CONDITIONS
MIN.
TYP.
MAX.
UNIT
I
I
Input current
V
IG
 = 5 V
20
90
160
µ
A
V
IG
Input clamping voltage
I
I
 = 200 
µ
A
5.5
7
8.5
V
V
IG(ON)
Input turn-on threshold voltage
-
2.4
3
V
V
IG(OFF)
Input turn-off threshold voltage
1.5
2.1
-
V
V
IG
Input turn-on hysteresis
-
0.3
-
V
I
I(ON)
Input turn-on current
V
IG
 = 3 V
-
-
100
µ
A
I
I(OFF)
Input turn-off current
V
IG
 = 1.5 V
10
-
-
µ
A
STATUS CHARACTERISTICS
The status output is an open drain transistor, and requires an external pull-up circuit to indicate a logic high.
Limits are at -40˚C 
 T
mb
 
 150˚C and typicals at T
mb
 = 25 ˚C unless otherwise stated.  Refer to 
TRUTH TABLE
.
SYMBOL
PARAMETER
CONDITIONS
MIN.
TYP.
MAX.
UNIT
V
SG
Status clamping voltage
I
S
 = 100 
µ
A
5.5
7
8.5
V
V
SG
Status low voltage
I
S
 = 100 
µ
A
-
-
1
V
T
mb
 = 25˚C
-
0.7
0.8
V
I
S
Status leakage current
V
SG
 = 5 V
-
-
15
µ
A
T
mb
 = 25˚C
-
0.1
1
µ
A
I
S
Status saturation current
1
V
SG
 = 5 V
2
7
12
mA
Application information
R
S
External pull-up resistor
-
47
-
k
Ω
OPEN CIRCUIT DETECTION CHARACTERISTICS
An open circuit load can be detected in the on-state.  Refer to 
TRUTH TABLE
.
Limits are at -40˚C 
 T
mb
 
 150˚C and typical is at T
mb
 = 25 ˚C.
SYMBOL
PARAMETER
CONDITIONS
MIN.
TYP.
MAX.
UNIT
Open circuit detection
9 V 
 V
BG
 
 35 V
I
L(TO)
Low current detect threshold
150
-
1000
mA
T
j
 = 25˚C
250
500
750
mA
I
L(TO)
Hysteresis
-
100
-
mA
In a fault condition with the pull-up resistor short circuited while the status transistor is conducting.  This condition should be avoided in order to
prevent possible interference with normal operation of the device.
September 2002
4