Philips BUK209-50Y ユーザーズマニュアル

ページ / 8
Philips Semiconductors
Product specification
 TOPFET high side switch
BUK214-50Y 
 SMD version of BUK209-50Y
 
UNDERVOLTAGE & OVERVOLTAGE CHARACTERISTICS
Limits are at -40˚C 
 T
mb
 
 150˚C and typicals at T
mb
 = 25 ˚C.  Refer to 
TRUTH TABLE
.
SYMBOL
PARAMETER
CONDITIONS
MIN.
TYP.
MAX.
UNIT
Undervoltage
V
BG(UV)
Low supply threshold voltage
1
2
4.2
5.5
V
V
BG(UV)
Hysteresis
-
0.5
-
V
Overvoltage
V
BG(OV)
High supply threshold voltage
2
40
45
50
V
V
BG(OV)
Hysteresis
-
1
-
V
TRUTH TABLE
ABNORMAL CONDITIONS
DETECTED
LOAD
INPUT
SUPPLY
LOAD
OUTPUT
STATUS
DESCRIPTION
UV
OV
LC
SC
OT
L
X
X
X
X
X
OFF
H
off
H
0
0
0
0
0
ON
H
on & normal
H
0
0
1
0
0
ON
L
on & low current detect
H
1
0
X
X
X
OFF
H
supply undervoltage lockout
H
0
1
X
0
0
OFF
H
supply overvoltage shutdown
H
0
0
0
1
X
OFF
L
SC tripped
H
0
0
0
0
1
OFF
L
OT shutdown
3
KEY TO ABBREVIATIONS
L
logic low
UV undervoltage
H
logic high
OV overvoltage
X
don’t care
LC
low current or open circuit load
0
condition not present
SC short circuit
1
condition present
OT overtemperature
Undervoltage sensor causes the device to switch off and reset.
Overvoltage sensor causes the device to switch off to protect its load.
The status will continue to indicate OT (even if the input goes low) until the device cools below the reset threshold.  Refer to 
OVERLOAD
PROTECTION CHARACTERISTICS
.
September 2002
5
Rev 2.000