SMC Networks 100 ユーザーズマニュアル

ページ / 90
M
AKING
 N
ETWORK
 C
ONNECTIONS
4-2
VF-45 Fiber Connections
Each device requires a 62.5/125 micron or 50/125 micron 
multimode fiber optic cable with VF-45 connectors at both ends. 
1. Remove and keep the VF-45 port’s plastic cover. When not 
connected to a fiber cable, the cover should be replaced to 
protect the optics.
2. Check that the fiber terminators are clean. You can clean the 
cable plugs using an appropriate VF-45 cleaning kit. Dirty fiber 
terminators on fiber optic cables will impair the quality of the 
light transmitted through the cable and lead to degraded 
performance on the port.
3. Connect one end of the cable to the VF-45 port on the switch 
and the other end to the VF-45 port on the other device. Since 
VF-45 connectors are keyed, the cable can be attached in only 
one orientation.
4. As each connection is made, check the Link LED on the 
switch’s front panel for the corresponding port to be sure that 
the connection is valid.
You can run a fiber link up to 2 km (1.24 mi.) in full-duplex mode, 
and 412 m (1351 ft.) in half-duplex mode. However, note that 
power budget and timing constraints must also be considered 
when calculating the maximum cable length for your specific 
environment.