SMC Networks 100 ユーザーズマニュアル

ページ / 90
M
AKING
 N
ETWORK
 C
ONNECTIONS
4-3
SC Fiber Connections
An optional slide-in 100BASE-FX module may be used for 
backbone and long distance connections. A 1000BASE-X module 
may also be used for a backbone connection between switches, or 
for connecting to a high-speed server.
Each multimode fiber optic port requires 50/125 or 62.5/125 
micron multimode fiber optic cabling with an SC connector at both 
ends. If you need to connect to a device with 62.5/125 micron 
cable that has ST-type connectors, SMC provides an optional SC-ST 
Converter (Part Number: 99-012034-091). 
Each single-mode fiber port requires 9/125 micron single-mode 
fiber optic cable with an SC connector at both ends.
Warning: This switch uses lasers to transmit signals over fiber 
optic cable. The lasers are compliant with the 
requirements of a Class 1 Laser Product and are 
inherently eye safe in normal operation. However, you 
should never look directly at a transmit port when it is 
powered on.
1. Remove and keep the SC port’s rubber cover. When not 
connected to a fiber cable, the rubber cover should be 
replaced to protect the optics.
2. Check that the fiber terminators are clean. You can clean the 
cable plugs by wiping them gently with a clean tissue or cotton 
ball moistened with a little ethanol. Dirty fiber terminators on 
fiber optic cables will impair the quality of the light transmitted 
through the cable and lead to degraded performance on the 
port.