Extron electronic MVX 88 Series ユーザーズマニュアル

ページ / 84
2-3
MVX 44 / 48 / 84 / 88 VGA Matrix Switchers • Installation
 
PRELIMINAR
Y
100-240V     0.3A
50-60Hz
MVX 88 V
GA A
RS-232
OUTPUTS
L
R
7
L
R
8
L
R
5
L
R
6
L
R
3
L
R
4
L
R
1
L
R
2
C
U S
LIS
TED
1T2
3
I.T.
E.
1
2
3
4
INPUTS
5
6
7
8
1
2
OUTPUTS
3
4
5
6
7
8
Rack-mount
Bracket (Included)
Table/
Wall-mount
Bracket (Optional)
Drill pilot holes
3/32” (2 mm) dia.,
1/4” (6 mm) deep.
#8 Screw (4 Plcs)
Each Side
Mounting Screws (2 Plcs)
Each Side
or
Figure 2-1 — Mounting the switcher
Furniture mounting the switcher
The MVX Series switchers can be mounted under a table or other horizontal surface 
with an optional Extron under-desk mounting kit (part #70-222-01).
1
Secure the two table/wall mounting brackets to the switcher with the eight 
machine screws provided in the kit (figure 2-1).
2
Hold the switcher with attached brackets against the underside of the desk or 
other furniture.  Mark the location of holes for screws on the underside of the 
desk.
3
Drill 1/4” (6.4 mm) deep, 3/32" (2 mm) diameter pilot holes in the table or 
desk at the marked screw locations from the underside/inside (concealed 
side) of the furniture, where the switcher will be located.
4
Insert the four wood screws into the pilot holes.  Fasten each screw into the 
installation surface until just less than 1/4" of the screw head protrudes.
5
Align the installed screws with the slots in the mounting brackets, and place 
the switcher against the surface, with the screws through the bracket slots.
6
Slide the switcher slightly forward or back, then tighten all four screws to 
fasten it in place.