Siemens X-400 ユーザーズマニュアル

ページ / 148
Installation and Commissioning 
Operating Instructions for SCALANCE X-400 Industrial Ethernet Switches 
C79000-G8976-C186-03 
111
6.8.4  LED Display - DI Module 
LED Display of the Digital Inputs 1 through 8 
The status of four digital inputs (IN1 through IN4 or IN5 through IN8) can be indi-
cated by the four LEDs on the front panel of the DI module. 
 
F
L 1
L 2
P o w e r   M o d u l e   L E D s
P o r t   -   L E D s
P 1
P 2
C P U   -   L E D s
R M
S T B Y
D M 1
D M 2
D I   -   L E D s
I N 1 / I N 5
I N 2 / I N 6
I N 3 / I N 7
I N 4 / I N 8
Figure 6-27 
LEDs of the digital inputs and display modes 
Four modes (display mode A through D) are available and these are displayed by 
two LEDs (DM1, DM2) on the Switch CPU. The display modes A and C are identi-
cal as are modes B and D. 
Mode DM1 
DM2 IN1/5 IN2/6 IN3/7 IN4/8 Meaning 
DMode A 
DMode C 
off off     Digital 
inputs 
IN1 through IN4 
 
 
 
on 
 
 
 
Signal at input IN1 
 
 
 
 
on 
 
 
Signal at input IN2 
 
    on 
 Signal 
at 
input 
IN3 
 
 
 
 
 
 
on 
Signal at input IN4 
 
Mode 
DM1 DM2 IN1/5 IN2/6 IN3/7 IN4/8 Meaning 
DMode B 
DMode D 
on off     Digital 
inputs 
IN5 through IN8 
 
  on 
   Signal 
at 
input 
IN5 
 
   on 
  Signal 
at 
input 
IN6 
 
    on 
 Signal 
at 
input 
IN7 
 
     on 
Signal 
at 
input 
IN8