Installation and Commissioning 
 
Operating Instructions for SCALANCE X-400 Industrial Ethernet Switches 
112 
C79000-G8976-C186-03 
6.8.5  LED Display - Switch CPU 
Display Modes A through D 
The set display modes are indicated as follows: 
 
D M o d e   A
D M o d e   B
D M o d e   C
D M o d e   D
R M
S T B Y
D M 1
D M 2
R M
S T B Y
D M 1
D M 2
R M
S T B Y
D M 1
D M 2
R M
S T B Y
D M 1
D M 2
Figure 6-28 
Display of the possible display modes (DMode A through DMode D) 
The individual functions (RM, STBY and DM1 / DM2) are independent of each 
other. The LED displays are described below: 
Label Color 
Status 
Meaning 
RM 
 
off 
The SCALANCE X414-3E is not operating 
in redundancy manager mode. 
 
Green 
on 
The SCALANCE X414-3E is operating in 
redundancy manager mode. The ring is 
working without problems, monitoring is 
activated. 
 
 
flashes  The SCALANCE X414-3E is operating in 
redundancy manager mode. An interruption 
has been detected on the ring; the 
SCALANCE X414-3E has switched through.
STBY 
 
off 
No function, reserved for future applica-
tions. 
DM1 
Green 
on 
Display of the display mode. 
DM2 
Green 
on 
Display of the display mode.