Siemens X-400 ユーザーズマニュアル

ページ / 148
Installation and Commissioning 
Operating Instructions for SCALANCE X-400 Industrial Ethernet Switches 
C79000-G8976-C186-03 
91
6.6.2  Connectors of the Signaling Contact and Grounding Strap (X2)  
The signaling contact is connected by contacts MK1 and MK2 on the 4-pin connec-
tor to the rear terminal block on the PS module. 
 
X 2
X 1
M K 2
G N D
M 3
M K 1
Figure 6-10 
Pin assignment of connector X2 
By inserting a strap between protective earth P and M3, the SCALANCE X414-3E 
switch can be operated with grounded reference potential. 
When the device ships, no strap is fitted (non-grounded reference potential). 
 
Conn. 2 
MK1 
Floating signaling contact relay connector 1 
 M3 
Ground 
 GND 
Protective 
earth 
 
MK2 
Floating signaling contact relay connector 2