Installation and Commissioning 
 
Operating Instructions for SCALANCE X-400 Industrial Ethernet Switches 
92 
C79000-G8976-C186-03 
6.6.3  Digital Input Connectors (X1) 
Polarity Reversal Protection X1, X2 
The two 5-pin male connectors (X1, X2) of the digital inputs 1 through 8 have no 
polarity reversal protection. If the connectors are accidentally swapped over, this 
does not cause damage or destroy circuits. In display modes A and C or B and D, 
incorrect inputs are displayed during the time the connectors are swapped over. 
Digital inputs 1 through 4 are connected using a 5-pin connector at the front termi-
nal block on the DI module. 
 
X 2
X 1
I N 2
M 4
I N 3
I N 4
I N 1
Figure 6-11 
Pin assignment of connector X1 (Inputs 1 through 4) 
 
Conn. 1 
IN1 
Digital input 1 
 
IN2 
Digital input 2 
 M4 
Ground 
 
IN3 
Digital input 3 
 
IN4 
Digital input 4 
 
!
 
Warning 
The input voltage must not exceed + 30 V and must not fall below – 30 V, other-
wise the DI module will be destroyed.