RPC SERIES OWNER’S MANUAL
RPC SERIES QUICK START (RPC-2 MD01 AND RPC-2 RDR)
________________________________________________________________________________
7
Controlling Receptacles
To set or change the status of the
receptacles, enter one of the following
commands:  ON n, OFF n, REBOOT n,
where “n” is the outlet number you want to
command.   Entering an outlet number of
“0” sends the command to all outlets.
Reboot only works on outlets which are in
the “ON” condition.
CONFIGURATION
Type “CONFIG” from the RPC>prompt.
The following menu appears:
RPC >CONFIG
1) . . . Change Password
2) . . . Change Outlet Name
Enter Request:
Change Password
Default password is <cr>.  The maximum
field length is 8 alphanumeric characters.
The password feature is case sensitive.
Change Outlet Name
Default Outlet Names are Outlet 1, Outlet
2, … 
The maximum field length is 10
alphanumeric characters.