Lathem LTR4-512 ユーザーズマニュアル

ページ / 23
LTRx-512 User’s Guide 
[3]=Manual Bell Control 
 
This function does not require a password 
 
Use this function to test bell circuits or to sound a bell during an unscheduled time, such as a 
fire alarm. Press [#][3][#] to start this function 
MANUAL BELL CONTROLS 
  1-2-3-4-5-6-7-8 
  PRESS AND HOLD [#] 
TO EXECUTE.[*]TO END
 
 
 
 
 
The 2
nd
 line of the display only shows the circuit numbers (1-8) that are available for bell 
controls 
 
Press [0] to turn them all off, or press keys [1] - [8] to turn a circuit off or on 
 
When you see the circuits that you want to ring, press and hold the [#] key. The green front 
panel lights will light up to show that you have turned on those relays. Release the [#] key to 
turn those relays back off. Note that the relays scheduled to turn ‘on’ will cycle as programmed 
 
You can now sound other circuits, or press [*] to quit 
 
Note: When your CLOCK1 Type is Type 14 (Electronic Coded) or Type 15 (Straight 
Frequency), you may need to hold the [#] key for about a minute to energize your bell circuits. 
You will know that your circuits have turned on when the green front panel lights for those 
circuits light up 
 
[4]=Program Schedules 
 
Use this function to set bell schedules. A schedule lists the days and times when the bell 
circuits will turn on. Your Master can have up to eight (8) different bell schedules with up to 
sixty-four (64) ‘events’ per schedule. If needed, you can make several schedules active at the 
same time to increase the number of events to as many as 512 (8 multiplied by 64). In fact, 
each ‘event’ can trigger several ‘actions’. For example, you can program a single event to turn 
on relays #1, #2 and #4 for 7 seconds at 08:00 AM on Tuesdays, Thursdays and Holidays 
 
Enter your password (#0#), then press [#][4][#] to start programming schedules   
SCHEDULE PROGRAMMING 
SELECT SCHEDULE #   N
 
 
 