Lathem LTR4-512 ユーザーズマニュアル

ページ / 23
LTRx-512 User’s Guide 
Enter your password (#0#), then press [#][9][#]. You will see a display similar to the 
following: 
       SELECT SYNCH CLOCKS 
       CLK[1]  &/OR  CLK[2]
 
 
Note: CLK[2] appears on the LTR8-512 and LTR8-512M only 
 
Since only one of the clock circuits may have lost power, you can choose to re-sync CLOCK1, 
CLOCK2 or both. 
 
 
Press [1] to turn on or off this display: 
 
  ADVANCE 
CLK1 
 
 
 
Press [2] to turn on or off this display (you will see this option only if your clock is setup 
for 2 Clock Systems.): 
 
  ADVANCE 
CLK2 
 
 
After choosing which clock circuits to sync, press [#].  
 
If your clocks are synchronous types (01, 03, 06, 18, 19 & 22), they can only advance to the 
start of the nearest hour and will then wait for the Master Clock to catch up. If your clocks are 
impulse types, then you will see  
Enter the time shown on the secondary clocks that have lost time, then press [#]. You will see 
 
   PRESS 
[#] 
TO 
EXECUTE 
 
To sync the secondary clocks, press [#], or press [*] to cancel. Your impulse clocks will 
advance to your LTRx-512’s time 
 
NOTES:  
1. The Clock Sync function does not support Clock Types 14, 15 or 24 
2. When a Power-On Clock Recovery or user-initiated clock sync occurs, your LTRx-512 will 
not accept other commands to start clock synchronization 
3. You can cancel Power-On Clock Recovery or user-initiated clock synchronization by 
choosing Clock Types again through function [2]=SELECT CLOCK CTL. 
 
[A]=Program Holidays 
 
You can enter up to 16 dates as holidays in your LTRx-512. During holidays, only the events 
that you set to occur on holidays will turn on when they reach the scheduled time. 
 
Examples: 
15