DEFINITY Enterprise Communications Server Release 8.2
Upgrades and Additions for R8r  
555-233-115  
Issue 1
April 2000
Adding or Removing Cabinet Hardware 
6-54
Add IP Interface Assembly 
6
.
6. If not, type MEDPRO in the slot just above TN802B slot and press 
Enter
Changing the one entry automatically changes the entry above it. If it is in 
IP Trunk mode, you get the following error message:
MedPro type requires TN802 with application. Type 
MEDPRO on circuit-packs form.
7. Type change ip-interfaces and press 
Enter
8. Type in the information for the TN802B IP Interface, 
9. Set the 
Enabled
 field to y, and press 
Enter
.
NOTE:
The customer provides the IP address, subnet mask, and gateway 
address.
At this time the TN802B LCD reads PC BOOT *, and about 3 to 4 minutes 
later reads MEDPRO * with the asterisk flashing
change circuit-packs                                            Page   1 of   5 
                              CIRCUIT PACKS                                     
        Cabinet: 1                            Carrier: A
                                         Carrier Type: processor        
 Slot Code  Sf Mode   Name               Slot Code  Sf Mode   Name
11:
MEDPRO RESERVED-IP
01: TN754 
DIGITAL LINE 
12:
MEDPRO 
RESERVED-IP
02: TN758 
POOLED MODEM 
13:
TN802  B 
MAPD BOARD
03: TN2144 
ANALOG LINE 
14: 
04: TN746  B 
ANALOG LINE 
15: 
05
16:         
06: TN771  C 
MAINTENANCE/TEST  
07: TN464  F 
DS1 INTERFACE     
08: TN2140 
E&M TIE TRUNK     
09: TN767  E 
DS1 INTERFACE     
10: TN799  B 
CONTROL-LAN       
  ’#’ indicates circuit pack conflict.