Lucent Technologies 555-233-115 Manuale Utente
DEFINITY Enterprise Communications Server Release 8.2
Upgrades and Additions for R8r
Upgrades and Additions for R8r
555-233-115
Issue 1
April 2000
Adding or Removing Cabinet Hardware
6-54
Add IP Interface Assembly
6
.
6. If not, type MEDPRO in the slot just above TN802B slot and press
Enter
.
Changing the one entry automatically changes the entry above it. If it is in
IP Trunk mode, you get the following error message:
IP Trunk mode, you get the following error message:
MedPro type requires TN802 with application. Type
MEDPRO on circuit-packs form.
7. Type change ip-interfaces and press
Enter
.
8. Type in the information for the TN802B IP Interface,
9. Set the
Enabled
field to y, and press
Enter
.
NOTE:
The customer provides the IP address, subnet mask, and gateway
address.
address.
At this time the TN802B LCD reads PC BOOT *, and about 3 to 4 minutes
later reads MEDPRO * with the asterisk flashing
later reads MEDPRO * with the asterisk flashing
change circuit-packs Page 1 of 5
CIRCUIT PACKS
CIRCUIT PACKS
Cabinet: 1 Carrier: A
Carrier Type: processor
Carrier Type: processor
Slot Code Sf Mode Name Slot Code Sf Mode Name
11:
MEDPRO RESERVED-IP
01: TN754
DIGITAL LINE
12:
MEDPRO
RESERVED-IP
02: TN758
POOLED MODEM
13:
TN802 B
MAPD BOARD
03: TN2144
ANALOG LINE
14:
04: TN746 B
ANALOG LINE
15:
05
16:
06: TN771 C
MAINTENANCE/TEST
07: TN464 F
DS1 INTERFACE
08: TN2140
E&M TIE TRUNK
09: TN767 E
DS1 INTERFACE
10: TN799 B
CONTROL-LAN
’#’ indicates circuit pack conflict.