Maintenance Object Repair Procedures 
Page 10-344
DATA-BD (Network Control Circuit Pack) 
10
Error Log Entries and Test to Clear Values
Notes:
a. This error indicates the DATA-BD portion of the Network Control circuit 
pack stopped functioning. Since the Network Control circuit pack cannot 
be reset via the 
reset board PCSS
 command, the Data Channel Reset 
Test (#107) in the Long Test Sequence for the DATA-CHLs and 
DATA-CON must be used to reset it as follows:
1. Issue the 
list data
 command to determine if one, or more, Network 
Control Data Channels (DATA-CHLs) is administered.
NOTE:
A Network Control Data Channel (DATA-CHL) is identified by 
a "type" value of "netcon."
2. If a Network Control Data Channel (DATA-CHL) is not administered, 
use the 
add data-module [<ext> | next]
 command to administer a 
DATA-CHL.
1.
Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the 
appropriate test description and follow the recommended procedures.
Table 10-110.
Network Control Circuit Pack Error Log Entries
Error 
Type
Aux 
Data
Associated Test
Alarm 
Level
On/Off 
Board
Test to Clear Value
0
1
0
Any
Any
Any
test data-module 
<ext> sh r 1
1 (a)
0
Data Channel Reset 
Test (#107)
MINOR
ON
test data-module 
<ext> l
23 (b)
0
None
WARNING
OFF
257
Any
Control Channel Test 
(#52)
MINOR
ON
test network-control 
[a | b] sh r 20
257 (c)
0
None
513 (d)
Any
None
769 (e)
4358
None
1025 (f)
4363
NPE Audit Test (#50)
test network-control 
[a | b] sh
1538 (g)
Data Channel Reset 
Test (#107)
MINOR
ON
test data-module 
<ext> l
3840 (h)
Any
None
3841(i)
Any
None
3999(j)
Any
None