Page 10-346
DATA-BD (Network Control Circuit Pack) 
10
Refer to “DATA-CHL” before issuing the 
test network- 
control [a | b] long
 command to determine if CDR, System 
Printer, Journal Printer, and/or PMS Links are using the 
DATA-CHLs and how to busyout these links prior to running 
destructive tests on the DATA-CHLs.
Refer to “SW-CTL” before issuing the 
test network-control 
[a | b] long
 command to determine the consequences of 
running the Switch Control Reset Test (Test #93).
4. Issue the 
test data-module <ext> long
 command using the 
extension for the DATA-CHL chosen in Step 3.
If the error happens again within 15 minutes, then replace the 
circuit pack.
h. This error is not service-affecting and no action is required.
i. In a High Critical Reliability system, the vintage number of the TN777B 
Network Control circuit pack must be greater than or equal to 17. The aux 
value for error 3841 indicates the vintage of the current TN777B installed.
j. Error type 3999
 Indicates that the circuit pack sent a large number of 
control channel messages to the switch within a short period of time. If 
error type 1538 is also present, then the circuit pack was taken 
out-of-service due to hyperactivity. If error type 1538 is not present, then 
the circuit pack has not been taken out-of-service, but it has generated 
50% of the messages necessary to be considered hyperactive. This may 
be completely normal during heavy traffic periods. However, if this error 
type is logged when the circuit pack is being lightly used, it may indicate a 
problem with the circuit pack or the equipment attached to it.
System Technician-Demanded Tests: 
Descriptions and Error Codes
Always investigate tests in the order presented in the table below. By clearing 
error codes associated with the 
NPE Audit Test
, for example, you may also clear 
errors generated from other tests in the testing sequence.
1.
D = Destructive; ND = Nondestructive
Order of Investigation
Short Test 
Sequence
Long Test 
Sequence
D/ND
1
NPE Audit Test (#50) (a)
X
ND
Control Channel Loop Around Test (#52)
X
X
ND