DIOD-TRK (DIOD Trunk) [G1.2SE]
10
3. PBX On-Hook (Drop Message): Open Tip-Ring loop, no loop current
a. CO Response: CO goes to idle state (see Note)
C. Direct Inward Dialing (DID)
1. CO Applies Ringing Voltage
a. PBX Response: Detect ringing current and close loop
b. CO Response: Send DTMF digits
c. PBX Response: Acknowledge of Number dialed and open loop
2. PBX Off-Hook (Answer Message): Close loop
a. CO Response: Trip ringing, provide loop current
3. PBX On-Hook (Drop Message): Open Tip-Ring loop, no loop current
a. CO Response: CO goes to idle state (see Note)
NOTE:
CO does not normally provide an On-Hook (Disconnect) signal.
CO does not normally provide an On-Hook (Disconnect) signal.
Hardware Error Log Entries and Test to Clear
Values
Values
Table 10-153.
DIOD Trunk Error Log Entries
Error
Type
Type
Aux
Data
Associated Test
Alarm
Level
On/Off
Board
Test to Clear Value
0
1
0
Any
Any
Any
test port PCSSpp sh r 1
15 (b)
any
Port Audit Update
Test (#36)
Test (#36)
18
0
busyout trunk
<grp>/<mbr>
<grp>/<mbr>
769 (a)
57392
None
MAJ/MIN/
WRN
WRN
2
ON
1537
Dial Tone Test (#0)
MAJ/MIN/
WRN
WRN
2
ON
test port PCSS l r 2
1793
Loop Around and
Conference Test
(#33)
Conference Test
(#33)
MAJ/MIN/
WRN
WRN
2
ON
test port PCSS l r 3
2049
NPE Cross Talk
Test (#6)
Test (#6)
MAJ/MIN/
WRN
WRN
2
ON
test port PCSS l r 3
2561
(a,d)
(a,d)
57345
None
2817 (a,e)
57393
None
Continued on next page