Maintenance Object Repair Procedures
Page 10-471
DIOD-TRK (DIOD Trunk) [G1.2SE]
10
Loop Around and Conference Circuit Test (#33)
This test checks the reflective loop and conference abilities of a CO port circuit.
The test uses 404 Hz, 1004 Hz, and 2804 Hz tones. Each tone is transmitted
separately through the loop and checked.
The test uses 404 Hz, 1004 Hz, and 2804 Hz tones. Each tone is transmitted
separately through the loop and checked.
PASS
The port is correctly using its allocated time slots. User-reported troubles
on this port should be investigated by using other port tests and by
examining trunk or external wiring.
on this port should be investigated by using other port tests and by
examining trunk or external wiring.
Table 10-157.
TEST #33 Loop Around and Conference Circuit Test
Error
Code
Code
Test
Result
Description/ Recommendation
ABORT
Could not allocate system resources to run this test.
7
ABORT
Conference Circuit Test aborted.
1000
ABORT
System resources required to run this test are not available. The port may
be busy with a valid call. Use the
be busy with a valid call. Use the
display port PCSSpp
command to
determine the trunk group/member number of the port. Use the
status
trunk
command to determine the service state of the port. If the service
state indicates that the port is in use, then the port is unavailable for certain
tests. (Refer to the "Status Commands" section in Chapter 10,
"Maintenance Commands and Trouble-Clearing Aids" for a full description
of all possible states.) You must wait until the port is idle before retesting.
tests. (Refer to the "Status Commands" section in Chapter 10,
"Maintenance Commands and Trouble-Clearing Aids" for a full description
of all possible states.) You must wait until the port is idle before retesting.
1. If the port status is idle, then retry the command at one-minute
intervals a maximum of five times.
2. If the test continues to abort, escalate the problem.
1004
ABORT
The port has been seized by a user for a valid call. Use the
status trunk
command to determine when the port is available for testing.
1. Retry the command at one-minute intervals a maximum of five times.
2. If the test continues to abort and the port is not in use, escalate the
problem.