Page 10-472
DIOD-TRK (DIOD Trunk) [G1.2SE] 
10
Port Audit Update Test (#36)
This test sends updates of the CO port translation for all ports on the circuit pack 
which have been translated. The update is non-disruptive and guards against 
possible corruption of translation data contained on the circuit pack. No 
response message is expected from the circuit pack once it receives translation 
updates. The port translation data includes: ground or loop start trunk, tone or 
rotary dialing trunk, rotary dialing inter-digit timing, network balance R/RC, and 
disconnect timing.
2100
ABORT
Could not allocate the necessary system resources to run this test.
1. Retry the command at one-minute intervals a maximum of five times.
2. If the test continues to abort, escalate the problem.
7
FAIL
1. Check for errors on TONE-BD or TONE-PT. If there are errors, take the 
appropriate actions.
2. If the Reflective Loop Around Test fails for all ports on a circuit pack, a 
-5 volt power problem is indicated. If a TN736 or TN752 power unit 
circuit pack is present, check the circuit pack for a red LED. If the red 
LED is on, then replace the appropriate power unit circuit pack. If 
neither the TN736 nor the TN752 power unit circuit pack is present, 
then the OLS631DB AC power unit may be defective. The system may 
contain a TN736 or TN752 power unit circuit pack OR an OLS631DB 
AC power unit, BUT NOT BOTH TYPES OF POWER UNITS.
NOTE:
To investigate problems with an OLD631DB AC power source, refer 
to CARR-POW Maintenance documentation.
3. Rerun the test.
4. If the test fails again, replace the circuit pack.
PASS
CO Trunk Loop Around and Conference Test is successful. User-reported 
troubles on this port should be investigated by using other port tests and 
by examining trunk or external wiring.
Table 10-157.
TEST #33 Loop Around and Conference Circuit Test  — 
Continued
Error 
Code
Test 
Result
Description/ Recommendation
Continued on next page