Page 10-499
DS1-BD (DS1 Interface Circuit Pack) 
10
Line Loopback Alarm
The Line Loopback (LLB) is used by the remote DS1 endpoint to put the ICSU or 
DS1 into a loopback mode. When the ICSU or DS1 Board is in the LLB mode, the 
arriving bit pattern is regenerated and sent back. Line Loopback (LLB) Alarm is 
activated when the in-band activate LLB bit pattern has been arriving 
continuously for 5 seconds on the DS1 line. LLB is deactivated when the in-band 
deactivate LLB bit pattern has been arriving continuously for 5 seconds on the 
DS1 line.
Since LLB is a maintenance condition rendering all DS0 channels unavailable for 
signaling or bearer traffic, maintenance software treats this the same as a Blue 
Alarm.
Payload Loopback Alarm
The Payload Loopback (PLB) is used by the remote DS1 endpoint to put the 
switch DS1 into a loopback mode. PLB Alarm is activated when a network 
protocol activate bit pattern arrives over the 4-Kbps ESF data link on the DS1 
line. PLB is deactivated when a network protocol deactivate bit pattern arrives 
over the 4-Kbps ESF data link on the DS1 line.
Since PLB is a maintenance condition rendering all DS0 channels unavailable for 
signaling or bearer traffic, maintenance software treats this the same as a Blue 
Alarm
Table 10-166.
TEST #139 Blue Alarm Inquiry Test 
Error 
Code
Test 
Result
Description/ Recommendation
ABORT
Internal system error
 2100
ABORT
Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals a maximum of 5 times.
Continued on next page