Maintenance Object Repair Procedures 
Page 10-501
DS1-BD (DS1 Interface Circuit Pack) 
10
Red Alarm Inquiry Test (#140)
DS1 Interface circuit pack raises a Red alarm when the framing pattern of the 
incoming DS1 bit stream has been lost. The Red Alarm Inquiry Test checks the 
framing status of a DS1 Interface circuit pack. DS1 Interface circuit pack takes 3 
seconds to recognize and report a Red alarm and 10 seconds to recognize and 
report the resolution of a Red alarm.
When the DS1 Interface circuit pack detects a Red alarm, the circuit pack will 
transmit a Yellow alarm to the remote DS1 endpoint and send a RED ALARM 
message to the maintenance software. After the Red alarm is confirmed, the 
maintenance software places all trunks of the circuit pack into the out-of-service 
state. The inquiry test will be run every 10 minutes until the Red alarm is cleared.
1795
FAIL
The DS1 Interface circuit pack detects a Payload Loopback Alarm (PLB). If the 
DS1 Interface circuit pack connects to a leased T1 facility, call the vendor of 
the T1 carrier to diagnose the remote DS1 endpoint. If the DS1 Interface circuit 
pack connects directly to another DS1 board, call the system technician of the 
remote switch to diagnose the DS1 endpoint.
 
PASS
Remote DS1 endpoint is in-service. Neither a Blue alarm nor a Line Loopback 
alarm nor a Payload Loopback alarm is detected in the DS1 Interface circuit 
pack.
0
NO 
BOARD
The test could not relate the internal ID to the port (no board). 
This could be due to incorrect translations, no board is inserted, an incorrect 
board is inserted, or an insane board is inserted.
1. Check to ensure that the board translations are correct. Use the 
add ds1 
PCSS
 command to administer the DS1 interface if it is not already 
administered.
2. If board was already administered correctly, check the error log to 
determine if the board is hyperactive. If this is the case, the board is shut 
down. Reseating the board will re-initialize the board.
3. If the board was found to be correctly inserted in step 1, issue the 
busyout 
board
 command.
4. Issue the 
reset board
 command.
5. Issue the 
release busy board
 command.
6. Issue the 
test board long
 command.
This should re-establish the link between the internal ID and the port.
Table 10-166.
TEST #139 Blue Alarm Inquiry Test  — 
Continued
Error 
Code
Test 
Result
Description/ Recommendation
Continued on next page