Maintenance Object Repair Procedures 
Page 10-808
MET-LINE (MET Line) 
10
1000
ABORT
System resources required to run this test are not available. The port may 
be busy with a valid call. Use the 
display port PCSSpp
 command to 
determine the station extension, attendant number, or trunk group/member 
number of the port. Use the 
status station
status attendant
, or 
status 
trunk
 command to determine the service state of the port. If the service 
state indicates that the port is in use, then the port is unavailable for certain 
tests. (Refer to the "Status Commands" section in 
 for a full description of all possible 
states.) You must wait until the port is idle before retesting. Attendants are 
always in use (off-hook) if the handset is plugged in and the port is not 
busied out.
1. If the port status is idle, then retry the command at one-minute 
intervals a maximum of five times.
2. If the test continues to abort, escalate the problem.
1001
ABORT
System resources required to run this test are not available. This could be 
due to a failure to seize the port.
1. Retry the command at 1-minute intervals a maximum of 5 times.
2. If the test continues to abort, escalate the problem.
1002
ABORT
The system could not allocate time slots for the test. The system may be 
under heavy traffic conditions or it may have time slots out-of-service due 
to TDM-BUS errors. Refer to TDM-BUS (TDM Bus) Maintenance 
documentation to diagnose any active TDM-BUS errors.
1. If system has no TDM-BUS errors and is not handling heavy traffic, 
repeat test at one-minute intervals a maximum of five times.
2. If the test continues to abort, escalate the problem.
1003
ABORT
The system could not allocate a tone receiver for the test. The system may 
be oversized for the number of Tone Detectors present or some Tone 
Detectors may be out-of-service.
1. Look for TTR-LEV errors in the Error Log. If present, refer to TTR-LEV 
(TTR Level) Maintenance documentation.
2. Look for TONE-PT errors in the Error Log. If present, refer to TONE-PT 
(Tone Generator) Maintenance documentation.
3. If neither condition exists, retry the test at one-minute intervals a 
maximum of five times.
4. If the test continues to abort, escalate the problem.
Table 10-271.
TEST #6 NPE Crosstalk Test  — 
Continued
Error 
Code
Test 
Result
Description/ Recommendation
Continued on next page