DEFINITY Enterprise Communications Server  Release 6
Maintenance for R6vs/si  
555-230-127   
Issue 1
August 1997
Maintenance Object Repair Procedures 
Page 10-810
MET-LINE (MET Line) 
10
Port Diagnostic Test (#35)
This test checks a port’s battery feed circuitry. The battery feed circuitry is tested 
for proper battery voltage by testing the switchhook state. In response to the test 
message, the on-board firmware terminates the line and checks for switch-hook 
presence. The termination is then removed, and a check is made for no 
switch-hook presence. The MET set must be on-hook for the test to execute.
Any
FAIL
This test can fail due to on-board or off-board problems. Off-board 
problems of concern include EXP-INTF faults, TDM-BUS faults, and faults 
associated with the tone detectors/tone generators. Clear all off-board 
problems before replacing the board. Keep in mind that a TDM-BUS 
problem is usually the result of a faulty board connected to the backplane 
or bent pins on the backplane.
1. Look for EXP-INTF errors in the error log. If present, refer to the 
EXP-INTF Maintenance documentation.
2. Look for TDM-BUS errors in the error log. If present, refer to the 
TDM-BUS Maintenance documentation.
3. Look for TONE-BD and/or TONE-PT errors in the error log. If present, 
refer to the TONE-BD Maintenance documentation and the TONE-PT 
Maintenance documentation.
4. Test the board when the faults from steps 1, 2, and 3 are cleared. 
Replace the board only if the test fails.
PASS
The port is correctly using its allocated time slots. User-reported troubles 
on this port should be investigated using other port tests and examining 
station, trunk, or external wiring.
0
NO 
BOARD
The test could not relate the internal ID to the port (no board). This could 
be due to incorrect translations, no board is inserted, an incorrect board is 
inserted, or an insane board is inserted.
1. Check to ensure that the board translations are correct. Use the 
list 
config
 command, and resolve any problems that are found.
2. If the board was found to be correctly inserted in step 1, issue the 
busyout board
 command.
3. Issue the 
reset board
 command.
4. Issue the 
release busy board
 command.
5. Issue the 
test board long
 command. This should re-establish the 
linkage between the internal ID and the port. If this is not the case, 
check to ensure that there is a valid board inserted.
Table 10-271.
TEST #6 NPE Crosstalk Test  — 
Continued
Error 
Code
Test 
Result
Description/ Recommendation
Continued on next page