Lucent Technologies lucent ユーザーズマニュアル

ページ / 2392
DEFINITY Enterprise Communications Server  Release 6
Maintenance for R6vs/si  
555-230-127   
Issue 1
August 1997
Maintenance Object Repair Procedures 
Page 10-865
M/T-ANL (Maintenance/Test Analog Port) 
10
M/T-ANL (Maintenance/Test Analog 
Port)
The Maintenance/Test Analog Port is port number 1 on the TN771 
Maintenance/Test circuit pack. This port is used by the Automatic Transmission 
Measurement System (ATMS) as an Originating Test Line (OTL) or Terminating 
Test Line (TTL) for test calls over analog trunks. 
 shows a typical 
ATMS configuration.
M/T-ANL maintenance ensures that the analog trunk’s testing function is 
operating correctly. An alarm against M/T-ANL can reduce service, but it will not 
block it. To accurately measure performance and health of analog trunks, the 
TN771 should be replaced when a new circuit pack is available.
Figure 10-71.
ATMS Tie Trunk Test Call
1.
Where P is the port network number (1 for PPN and 2 or 3 for EPN); C is the carrier designation 
(for example, A, B, C, D, or E); and SS is the address of the slot in the carrier where the circuit 
pack is located (for example, 01, 02, ..., etc.).
MO Name (in 
Alarm Log)
Alarm 
Level
Initial Command to Run
1
Full Name of MO
M/T-ANL
Minor
test port PCSSpp l 
Maintenance/Test Analog Port
M/T-ANL
Warning
release port PCSSpp 
Maintenance/Test Analog Port
Tie
Trunk
Facilities
Originating
Test Line
(OTL)
TN771
TDM Bus
Terminating
Test Line
(TTL)
TN771
TDM Bus
PBX originating
the test call
PBX terminating
the test call
Tie Trunk
Circuit Pack
Tie Trunk
Circuit Pack