Lucent Technologies lucent ユーザーズマニュアル

ページ / 2392
DEFINITY Enterprise Communications Server  Release 6
Maintenance for R6vs/si  
555-230-127   
Issue 1
August 1997
Maintenance Object Repair Procedures 
Page 10-867
M/T-ANL (Maintenance/Test Analog Port) 
10
System Technician-Demanded Tests: 
Descriptions and Error Codes
Always investigate tests in the order presented in the following tables when 
inspecting errors in the system. By clearing error codes associated with the 
Analog Port Sanity Test
, for example, you may also clear errors generated from 
other tests in the testing sequence.
NPE Crosstalk Test (#9)
The NPE Crosstalk Test verifies that this port’s NPE channel talks on the selected 
time slot and never crosses over to time slots reserved for other connections.
One or more Network Processing Elements (NPE) reside on each circuit pack 
with a TDM Bus interface. The NPE controls port connectivity, gain, and provides 
conferencing functions on a per port basis. If the NPE is not working correctly, 
one way and/or noisy connections may be observed. This test is part of a port’s 
long test sequence and takes approximately 10 to 20 seconds to complete
1.
D = Destructive; ND = Nondestructive
Order of Investigation
Short Test 
Sequence
Long Test 
Sequence
D/ND
1
Analog Port Sanity Test (#963)
X
X
ND
Digital Loop Around Test (#13)
X
X
ND
NPE Crosstalk Test (#9)
X
ND
Hook State Inquiry (#566)
X
X
ND
Clear Error Counters (#270)
X
ND