Lucent Technologies lucent ユーザーズマニュアル

ページ / 2392
DEFINITY Enterprise Communications Server  Release 6
Maintenance for R6vs/si  
555-230-127   
Issue 1
August 1997
Maintenance Object Repair Procedures 
Page 10-974
PI-SCI (System Communication Interface) 
10
PI-SCI (System Communication 
Interface)
!
WARNING:
The "test interface long" command resets the PI-BD and causes all 
ISDN-PRI and BX.25 links to come down.
The PI-SCI (System Communication Interface) MO is used to put the TN765 
Processor Interface circuit pack into a state such that BX.25 (DCS, AUDIX, etc.) 
and ISDN links can be established. The TN765 Processor Interface circuit pack 
has downloadable firmware. It is the responsibility of PI-SCI to download the 
firmware to the TN765 circuit pack during initialization. Failures while 
communicating with the TN765 circuit pack are logged against the PI-SCI MO. 
There can be up to two SCIs. There is a one-to-one correlation of PI-SCI to 
Processor Interface circuit packs. In a High or Critical Reliability system, there 
can be four Processor Interface circuit packs, but only two on the same carrier 
are active at any one time. If errors against the SCI can be related to the 
Processor Interface circuit pack, then the circuit pack MO is alarmed (PI-BD). 
See also PI-LINK (Processor Interface Link) and PI-BD (Processor Interface 
Circuit Pack) Maintenance documentation.
When investigating BX.25 (DCS, AUDIX, etc.) and ISDN link problems, resolve 
PI-SCI errors initially, since they might clear up the Processor Interface link 
problems.
1.
Where P is the port network number (1 for PPN only); C is the carrier designation (for example, A or 
B for processor complex circuit packs); and S is the address of the slot in the carrier where the 
circuit pack is located (for example, 1 or 2 for Processor Interface circuit packs 1 or 2).
2.
For additional repair information, see also PI-BD (Processor Interface Circuit Pack) Maintenance 
documentation.
MO Name (in 
Alarm Log)
Alarm 
Level
Initial Command to Run
1
Full Name of MO
PI-SCI
2
MAJOR
test interface PCS
System Communication Interface