Lucent Technologies lucent ユーザーズマニュアル

ページ / 2392
DEFINITY Enterprise Communications Server  Release 6
Maintenance for R6vs/si  
555-230-127   
Issue 1
August 1997
Maintenance Object Repair Procedures 
Page 10-975
PI-SCI (System Communication Interface) 
10
Error Log Entries and Test to Clear Values
1.
Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the 
appropriate test description and follow the recommended procedures.
2.
See WARNING below.
!
WARNING:
The "test interface long" command resets the PI-BD and causes all ISDN-PRI and 
BX.25 links to come down.
3.
Major alarms may be downgraded to Warning alarms based on the value used in the 
set options
 
command.
Table 10-331.
PI-SCI System Communication Interface Error Log Entries
Error 
Type
Aux 
Data
Associated Test
Alarm Level
On/Off 
Board
Test to Clear Value
0
1
0
Any
Any
Any
test interface PCS sh r 1
1 (a)
2055 
2056 
2057 
2058
none
none
none
none
257 (b)
Any
none
MAJOR
ON
test interface PCS l
2
769 (c)
Any
none
MAJOR/ 
WARNING
3
OFF
test interface PCS l
1025 (d)
Any
none
MAJOR/ 
WARNING
OFF
test interface PCS l
1281 (e)
Any
Sci Start Test (#176)
MAJOR/ 
WARNING
OFF
test interface PCS l
1793 (f)
Any
none
MAJOR
ON
test interface PCS l
2049 (g)
90xx 
Sci Start Test (#176)
MAJOR
ON
test interface PCS l
2305 (f)
Any
Sci Self Test (#231)
MAJOR
ON
test interface
PCS sh r 2
2561 (h)
Any
none
MAJOR/ 
WARNING
OFF
test interface PCS l
2817 (i)
Any
none
MAJOR/ 
WARNING
OFF
test interface PCS l
2818 (j)
Any
none
MAJOR/ 
WARNING
OFF
test interface PCS l
3073 (f)
Any
none
MAJOR/ 
WARNING
OFF
test interface PCS l