Maintenance Object Repair Procedures 
Page 10-978
PI-SCI (System Communication Interface) 
10
i. Error while communicating with TN765 Processor Interface circuit pack. 
See Note (b) for recovery. System software problem internal to the 
process that monitors Processor Interface link activity. Escalate the 
problem if error causes the Processor Interface to be reset (loss of service 
is noticed).
j. This error indicates that the TN765 Processor Interface circuit pack did not 
clear up the overload condition within one minute of logging the initial 
2817 error (overload detected). The circuit pack was reset and all 
Processor Interface links on that circuit pack were also reset.
Short and Long Test Sequences
The SCI and Processor Interface circuit pack are both tested via the same 
system technician command. The system technician command is 
test interface 
PCS l
 or 
sh
 where PCS is an active Processor Interface circuit pack.
!
WARNING:
The "test interface long" command resets the PI-BD and causes all 
ISDN-PRI and BX.25 links to come down.
For information about testing the Standby Processor Interface circuit pack, see 
PI-BD Maintenance documentation. If the Active Processor Interface has no 
enabled links (see Communication-Interface Links Form in 
, only XXX-BD (Common 
Port Circuit Pack) tests execute.
System Technician Demanded Tests: 
Descriptions and Error Codes
Always investigate tests in the order presented in the table below when 
inspecting errors in the system. By clearing error codes associated with the 
SCI 
Start Test,
 for example, you may also clear errors generated from other tests in 
the testing sequence