DEFINITY Enterprise Communications Server  Release 6
Maintenance for R6vs/si  
555-230-127   
Issue 1
August 1997
Maintenance Object Repair Procedures 
Page 10-979
PI-SCI (System Communication Interface) 
10
.
a. For information about these tests, refer to the XXX-BD (Common Port 
Circuit Pack) Maintenance documentation. These tests are run on the 
PI-BD (Processor Interface Circuit Pack) Maintenance object.
SCI Start Test (#176)
This test is destructive.
This test restarts the System Communication Interface. This implies all BX.25 
(DCS, AUDIX, mis, etc.) and ISDN links are restarted. The checksum of the 
downloadable firmware is tested. If the checksum fails, the firmware is 
redownloaded from tape. If it passes, SCI Start completes and the associated 
BX.25 and ISDN Links are started up. If a circuit pack needs to be replaced, refer 
to 
 for instructions on 
replacing an SPE circuit pack.
The Processor Interface circuit pack firmware is downloaded from the flash ROM 
memory of Processor circuit pack. If the checksum test fails, then the firmware is 
re-downloaded again from Processor circuit pack. If it passes, SCI Start 
completes and the associated BX.25 and ISDN links are started up. If the 
checksum failure persists, refer the footnote (b) of Hardware Error Table for 
repair procedure.
1.
D = Destructive; ND = Nondestructive
Order of Investigation
Short Test 
Sequence
Long Test 
Sequence
D/ND
1
SCI Start Test (#176)
X
D
SCI Self Test (#231)
X
X
ND
Control Channel Loop Test (#52) (a)
X
X
ND
NPE Audit Test (#50) (a)
X
ND
Table 10-332.
TEST #176 SCI Start Test 
Error 
Code
Test 
Result
Description/ Recommendation
 9
10
ABORT
Internal system error
1. Retry the command at 1-minute intervals a maximum of 5 times.
Continued on next page