STRAT-3 (Stratum 3 Clock)] 
10
NOTE:
When looking in the Stratum 3 cabinet, "A" card is on the left and "B" card is 
on the right.
Hardware Error Log Entries and Test to Clear 
Values
Notes:
a. In the context of the Stratum 3 clock, an OFF-BOARD alarm occurs when 
there is a DS1 facility problem; otherwise, the alarm is ON-BOARD 
indicating that there is a fault in the Stratum 3 clock or in the connection 
between the Stratum 3 clock and the PBX (Private Branch Exchange) 
switch. If the Stratum 3 clock cannot be referenced, and therefore the 
local oscillator on the TN780 Tone-Clock circuit pack must serve as the 
reference instead, a Major alarm is raised. Otherwise, a Minor alarm is 
raised.
b. This error can be caused by one of the following conditions:
1. One or both TOCs (Timing Output Cards) may have failed,
1.
Run the Short Test Sequence. Refer to the appropriate test description and follow the recommended 
procedures.
Stratum 3 Clock Error Log Entries
Error 
Type
Aux 
Data
Associated Test
Alarm Level
On/Off
 Board
Test to Clear Value
0
1
0
Any
Any
Any
test synchronization r 4
1 (d)
Any
Stratum 3 Clock 
Alarm Query (#649)
MINOR
OFF
test synchronization r 4
257 (e)
Any
Stratum 3 Clock 
Alarm Query (#649)
MINOR
OFF
test synchronization r 4
257 (c)
None
WARNING
ON
513 (f)
Any
Stratum 3 Clock 
Alarm Query (#649)
MINOR
ON
test synchronization r 4
769 (g)
Any
Stratum 3 Clock 
Alarm Query (#649)
MINOR
ON
test synchronization r 4
1025 (h)
Any
Stratum 3 Clock 
Alarm Query (#649)
MINOR/ MAJOR(a)
ON
test synchronization r 4
1281 (i)
Any
Stratum 3 Clock 
Alarm Query (#649)
MINOR/ MAJOR(a)
ON
test synchronization r 4
1537 (b)
none
MINOR/ MAJOR(a)
ON