Lucent Technologies lucent ユーザーズマニュアル

ページ / 2392
DEFINITY Enterprise Communications Server  Release 6
Maintenance for R6vs/si  
555-230-127   
Issue 1
August 1997
Maintenance Object Repair Procedures 
Page 10-1240
TAPE (Tape Unit) [G3iV1.1-286] 
10
n. [G1.1 and earlier] If these errors occur in conjunction with Error Type 
#3329, a major alarm is logged against the error type. To resolve this 
alarm, follow the instructions for Error Type #3329.
o. [G1.1 and earlier] "Leaky Bucket" strategy for Error Types #1793, #1828, 
#2049, #2051, and #2084 on the Active SPE. Whenever any of these 
errors appear in the Error Log, they will be automatically resolved within 48 
hours if the errors do not recur within that period. In G1.0, this is the only 
way these errors can be cleared (without resetting the system).
System Technician Demanded Tests: 
Descriptions and Error Codes
Always investigate tests in the order they are presented in the table below when 
inspecting errors in the system. By clearing error codes associated with the 
Tape 
DMA Latch Test
 for example, you may also clear errors generated from other 
tests in the testing sequence.
Notes:
a. The Tape Read/Write Test only runs in the following software releases;
G1
G3iV1, EDI 6.0 and earlier.
b. The Tape Block Error Test runs only in software release G3iV1, EDI 15.0 
and earlier.
c. Refer to TAPE-DAT (Tape Consistency) Maintenance documentation for 
the description of this test.
1.
D = Destructive; ND = Nondestructive
Order of Investigation
Short Test 
Sequence
Long Test 
Sequence
D/ND
1
Tape Reset Test (#67)
X
ND
Tape DMA Latch Test (#230)
X
X
ND
Tape Diagnostic Test (#66)
X
X
ND
Tape Read/Write Test (#65) (a)
X
ND
Tape Block Error Test (#692) (b)
X
ND
Tape Status Test (#69)
X
X
ND
Tape Translation Status Test (#505)
X
ND
TAPE-DAT Tape Consistency Test (#421) (c)
X
ND