Page 10-1242
TAPE (Tape Unit) [G3iV1.1-286] 
10
Tape Reset Test (#67)
This test resets the tape portion of the Processor on the Maintenance/Tape 
Processor (PR-MAINT), and it resets the shared RAM on the Processor circuit 
pack (TN770). The test can pass when no drive is present because it never 
accesses the tape drive.
Status Request Test (#69)
This test requests the Maintenance/Tape Processor (MTP) firmware on the TN773 
Processor circuit pack for the current Tape Unit status and displays the results.
Table 10-427.
TEST #66 Tape Diagnostic Test 
Error 
Code
Test 
Result
Description/ Recommendation
1029 to 
2051
ABORT
Refer to the STBY-SPE (Standby SPE) Maintenance documentation for 
a description of these error codes.
9000’s
ABORT or 
FAIL
Refer to Table A in 
 and follow 
the recommended repair strategy for specific Aux Data.
Any 
Others
ABORT or 
FAIL
Refer to Table B in 
 and follow 
the recommended repair strategy for specific Aux Data.
PASS
This is a comprehensive test of the Tape Unit. The test verifies that the 
tape drive is in good working order.
Continued on next page
Table 10-428.
TEST #67 Tape Reset Test 
Error 
Code
Test 
Result
Description/ Recommendation
1029 to 
2051
ABORT
Refer to the STBY-SPE (Standby SPE) Maintenance documentation for a 
description of these error codes.
9000’s
FAIL
Refer to Table A in 
 and follow the 
recommended repair strategy for specific Aux Data.
Any 
Others
FAIL
Refer to Table B in 
 and follow the 
recommended repair strategy for specific Aux Data.
PASS
Communication with the tape processor is possible at a very basic level.