Lucent Technologies lucent ユーザーズマニュアル
DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si
Maintenance for R6vs/si
555-230-127
Issue 1
August 1997
Maintenance Object Repair Procedures
Page 10-1242
TAPE (Tape Unit) [G3iV1.1-286]
10
Tape Reset Test (#67)
This test resets the tape portion of the Processor on the Maintenance/Tape
Processor (PR-MAINT), and it resets the shared RAM on the Processor circuit
pack (TN770). The test can pass when no drive is present because it never
accesses the tape drive.
Processor (PR-MAINT), and it resets the shared RAM on the Processor circuit
pack (TN770). The test can pass when no drive is present because it never
accesses the tape drive.
Status Request Test (#69)
This test requests the Maintenance/Tape Processor (MTP) firmware on the TN773
Processor circuit pack for the current Tape Unit status and displays the results.
Processor circuit pack for the current Tape Unit status and displays the results.
Table 10-427.
TEST #66 Tape Diagnostic Test
Error
Code
Code
Test
Result
Description/ Recommendation
1029 to
2051
2051
ABORT
Refer to the STBY-SPE (Standby SPE) Maintenance documentation for
a description of these error codes.
a description of these error codes.
9000’s
ABORT or
FAIL
FAIL
Refer to Table A in
and follow
the recommended repair strategy for specific Aux Data.
Any
Others
Others
ABORT or
FAIL
FAIL
Refer to Table B in
and follow
the recommended repair strategy for specific Aux Data.
PASS
This is a comprehensive test of the Tape Unit. The test verifies that the
tape drive is in good working order.
tape drive is in good working order.
Continued on next page
Table 10-428.
TEST #67 Tape Reset Test
Error
Code
Code
Test
Result
Description/ Recommendation
1029 to
2051
2051
ABORT
Refer to the STBY-SPE (Standby SPE) Maintenance documentation for a
description of these error codes.
description of these error codes.
9000’s
FAIL
and follow the
recommended repair strategy for specific Aux Data.
Any
Others
Others
FAIL
and follow the
recommended repair strategy for specific Aux Data.
PASS
Communication with the tape processor is possible at a very basic level.
Continued on next page