Lucent Technologies lucent ユーザーズマニュアル

ページ / 2392
DEFINITY Enterprise Communications Server  Release 6
Maintenance for R6vs/si  
555-230-127   
Issue 1
August 1997
Maintenance Object Repair Procedures 
Page 10-1287
TBRI-PT (TN2185 ISDN Trunk-Side BRI Port) 
10
System Technician-Demanded Tests: 
Descriptions and Error Codes
When inspecting errors in the system, always investigate tests in the order listed 
below. By clearing error codes associated with the 
Control Channel Loop Around 
Test,
 for example, you may also clear errors generated from other tests in the 
testing sequence.
Clear Error Counters Test (#270)
This test is nondestructive.
1.
D = Destructive; ND = Nondestructive
66
admin/sub
Channel type not implemented
69
admin/sub
Requested facility not implemented 
70
admin/sub
Only restricted digital BC available
79
admin
Service/option not implemented
88
admin
Incompatible destination
102
switch problems
 Recovery on timer expired
Order of Investigation
Short Test 
Sequence
Long Test 
Sequence
D/ND
1
BRI Local LAN Port Loop Around Test (#618)
X
D
BRI TDM Port Loop Around Test (#619)
X
D
L1 State Query Test (#1242)
X
X
D
CRC Error Counter Test (#623)
X
ND
Receive FIFO Overflow Test (#625)
X
ND
Layer 3 Query Test (#1243)
X
ND
Slip Query Test (#1244)
X
X
ND
Clear Error Counters Test (#270)
X
X
ND
NPE Crosstalk Test (#617)
X
D
Table 10-441.
Cause Values for Error 3841-3942
Value
Type of Problem
Meaning