DEFINITY Enterprise Communications Server  Release 6
Maintenance for R6vs/si  
555-230-127   
Issue 1
August 1997
Maintenance Object Repair Procedures 
Page 10-1291
TBRI-PT (TN2185 ISDN Trunk-Side BRI Port) 
10
BRI Port Local TDM Looparound Test (#619)
This test is conditionally destructive
.
This test verifies the connectivity of a BRI port across the TDM Bus. It aborts if 
calls associated with the port are in progress. Failure of this test indicates an 
on-board fault associated with the port hardware on the circuit pack.
This Looparound Test runs the following individual tests on the two B-channels 
(B1 and B2) associated with the port.
A Looparound Test across the TDM Bus for B1.
A Conference Circuit Test for B1.
A Looparound Test across the TDM Bus for B2.
A Conference Circuit Test for B2.
The tests are run in the above order. If one fails, the remaining tests in the 
sequence are not executed, and maintenance software returns an error code.
FAIL
The Looparound Test has failed.
1. If the test fails repeatedly, attempt to reset the circuit pack with the 
busyout board PCSS
 and the 
reset board PCSS
 commands if the 
other ports on the board are not in use.
2. If the test fails again, execute 
test pkt P
. If this fails, follow failure 
procedures in the PKT-BUS section.
3. If the tests in Step 2 pass, the problem is local to the BRI board. 
Replace the trunk circuit pack.
PASS
The BRI Port Local LAN Looparound Test passed.
Table 10-444.
TEST #618 BRI Port Local LAN Loop Around  — 
Continued
Error 
Code
Test 
Result
Description/ Recommendation