Maintenance Object Repair Procedures 
Page 10-1449
UDS1-BD (UDS1 Interface Circuit Pack) 
10
NPE Connection Audit Test (#50)
The system sends a message to the on-board microprocessor to update the 
network connectivity translation for the SCOTCH-NPE chip on the circuit pack.
1.
D = Destructive; ND = Nondestructive
Far CSU Loopback Test 
(#1213)
X
D
One-Way Span Test 
(#1214)
X
D
Inject Single Bit Error 
(#1215)
X
D
End Loopback/Span Test 
(#1216)
X
D
Table 10-490.
TEST #50 NPE Connection Audit Test 
Error 
Code
Test 
Result
Description/ Recommendation
None 
2100
ABORT
System resources required for this test are not available.
1. Retry the command at 1-minute intervals a maximum of 5 times.
2. If the test continues to abort, escalate the problem.
1019
ABORT
The test aborted because a test was already running on the port.
1. Retry the command at 1 minute intervals for a maximum of 5 times.
2. If the test continues to abort, escalate the problem.
FAIL
Internal System Error
1. Retry the command at 1-minute intervals a maximum of 5 times.
2. If the test continues to abort/fail, escalate the problem.
PASS
The circuit pack’s SCOTCH-NPE chip have been updated with its 
translation.
Continued on next page
Table 10-489.
System Technician-Demanded Tests: Descriptions and Error Codes — 
Continued
Order of Investigation
Short Test 
Sequence
Long Test 
Sequence
Reset Board 
Sequence
test ds1-loop 
Command
 D/ND
1
Continued on next page