DEFINITY Enterprise Communications Server  Release 6
Maintenance for R6vs/si  
555-230-127   
Issue 1
August 1997
Maintenance Object Repair Procedures 
Page 10-1450
UDS1-BD (UDS1 Interface Circuit Pack) 
10
Control Channel Loop Around Test (#52)
This test queries the circuit pack for its circuit pack code and vintage and verifies 
its records.
0
NO 
BOARD
The test could not relate the internal ID to the port (no board). This could 
be due to incorrect translations, no board is inserted, an incorrect board is 
inserted, or an insane board is inserted.
1. Ensure that the board translations are correct. Execute the 
add ds1 
PCSS
 command to administer the UDS1 interface if it is not already 
administered.
2. If the board was already administered correctly, check the error log to 
determine whether the board is hyperactive. If this is the case, the 
board is shut down. Reseating the board will re-initialize the board.
3. If the board was found to be correctly inserted in step 1, then issue the 
busyout board
 command.
4. Issue the 
reset board
 command.
5. Issue the 
release busy board
 command.
6. Issue the 
test board long
 command.
This should re-establish the linkage between the internal ID and the port.
Table 10-491.
TEST #52 Control Channel Loop Around Test 
Error 
Code
Test 
Result
Description/ Recommendation
None 
2100
ABORT
System resources required for this test are not available.
1. Retry the command at 1-minute intervals a maximum of 5 times.
2. If the test continues to abort, escalate the problem.
Continued on next page
Table 10-490.
TEST #50 NPE Connection Audit Test  — 
Continued
Error 
Code
Test 
Result
Description/ Recommendation
Continued on next page