Error Messages 
Page A-106
test alarms 
A
Field Help
Following are the help messages that the system technician will see upon tabbing to the 
specified field and pressing the HELP key.
Major?
"n(o) y(es)"
Minor?
"n(o) y(es)"
Warning?
"n(o) y(es)"
Interval:
"m(onth), h(our), d(ay), w(eek), a(ll)"
From month
"Enter month between 1-12"
From (day)
"Enter day between 0-31"
From (hour)
"Enter hour between 0-23"
From (minute)
"Enter minute between 0-59"
To (month)
"Enter month between 1-12"
To (day)
"Enter day between 0-31"
To (hour)
"Enter hour between 0-23"
To (minute)
"Enter minute between 0-59"
Cabinet:
"Enter cabinet number (1-3)"
Port Network:
"Enter port network number (1-3)"
Board Number:
"Enter 4 character board number; 
[cabinet(1-3)]:carrier(A-E):slot(0-21)"
Port:
"Enter port number; 
[cabinet(1-3)]:carrier(A-E):slot(0-21):circuit(1-24)"
Category:
"adm-conn, announce, bri/asai, card-mem, cdr, 
data-mod, detector, dup-spe, environ, ext-intf, ext-dev, 
generatr, inads-link, infc, maint, mbus, memory, misc, 
mnt-test, modem, netcon, pkt, pkt_ctrl, quick-st, pms/jrnl, 
procr, s-syn, stabd, stacrk, stations, sys-prnt, tape, tdm, 
tone, trkbd, trkcrk, trunks and wideband" (For a table 
describing the category entries in greater detail, see the 
"display errors" command.)
Extension:
"Enter assigned extension, or blank"
Trunk (group)
"Enter group number between 1-99"
Trunk (member)
"Enter group member between 1-99, or blank"