Lucent Technologies lucent ユーザーズマニュアル

ページ / 2392
DEFINITY Enterprise Communications Server  Release 6
Maintenance for R6vs/si  
555-230-127   
Issue 1
August 1997
Error Messages 
Page A-108
test analog-testcall 
A
test analog-testcall
Help Messages
If the system technician presses 
HELP
 after entering "test analog-testcall" a message 
showing the following keywords is displayed:
trunk  board     port
If the system technician presses 
HELP
 after entering "test analog-testcall trunk," the 
following message will be displayed:
Enter group number or group number/member number,
[’full’ or ’supervision’ or   ’no-selftest’
or ’no-return-loss’ or ’no-st-or-rl’],
[’repeat 1-100’], [’schedule’]
If the system technician presses 
HELP
 after entering "test analog-testcall port" the 
following message will be displayed:
Enter trunk port number [’full’ or ’supervision’ 
or ’no-selftest’ or’no-return-loss’ 
or ’no-st-or-rl’], [’repeat 1-100’], [’schedule’]
If the system technician presses 
HELP
 after entering "test analog-testcall board" the 
following message will be displayed:
Enter trunk board number, [’full’ or ’supervision’
or ’no-selftest’ or ’no-return-loss’ 
or ’no-st-or-rl’], [’repeat 1-100’], [’schedule’]
Error Messages
If the format for the trunk location is incorrect, the following message displays:
Format invalid
If the trunk group or member range is invalid, the following message displays:
Trunk or trunk group invalid
Extension:
"Entry must be all digits"
"Extension not assigned"
Trunk (group)
"Entry must be all digits"
"Group not assigned, or group assigned but with no member"
Trunk (member)
"Entry must be all digits"
"Number invalid""
"Group member not assigned"
"Trunk or trunk group invalid"