DEFINITY Enterprise Communications Server  Release 6
Maintenance for R6vs/si  
555-230-127   
Issue 1
August 1997
Error Messages 
Page A-115
test ds1-loop 
A
Error Messages
If the format for the board location is incorrect, the following error message will be 
displayed:
Port/Board invalid
If the EPN in which the specified board resides is not available, the following message 
will be displayed:
EPN is not available
If the specified board is not inserted in the system, the following message will be 
displayed:
 Board not inserted
If the command entered is in conflict with another currently executing command, then a 
message will be displayed showing the login id of the conflicting user and the conflicting 
command. The message is as follows:
 ’login id’:’command’ has a command conflict
If during the execution of a command a resource problem occurs that requires the user 
to restart the command, then the following message will be displayed:
 Command resources busy; Press CANCEL to clear, and then resubmit
If all of the available maintenance resources are currently in use, then the following 
message will be displayed:
 All maintenance resources busy; try again later
If the "test ds1-loop" command is executed and the "Version" field on the 
"system-parameters customer-options" form is not V5 or later, then the following 
message will be displayed:
 G3 Version must be V5 or later
If the "test ds1-loop" command is executed on a circuit pack other than TN464F or 
TN767E or later DS1 board, then the following message will be displayed:
 Command valid for TN464F or TN767E or 
later release DS1 circuit packs
If the "inject-single-bit-error" parameter is selected, but no CPE Loopback Jack, far-end 
CSU, or one-way span test is active on the DS1 circuit pack, then the following message 
will be displayed:
 Parameter valid only if a loopback/span test is active on the DS1