Lucent Technologies lucent ユーザーズマニュアル

ページ / 2392
DEFINITY Enterprise Communications Server  Release 6
Maintenance for R6vs/si  
555-230-127   
Issue 1
August 1997
Error Messages 
Page A-113
test customer-alarm 
A
If all of the available maintenance resources are currently in use, then the following 
message will be displayed:
All maintenance resources busy; try again later
test customer-alarm
Help Messages
If the system technician presses 
HELP
 after entering "test customer-alarm" on a simplex 
SPE system, the following message will be displayed:
Enter [cabinet(1-3)],[’long’ or ’short’],
  [’repeat’(1-100) or ’clear’], [’schedule’]
If the system technician presses 
HELP
 after entering "test customer-alarm" on a duplex 
SPE system the following message will be displayed:
For cabinet 1 enter [cabinet(1)];
carrier (A-B),[’long’ or ’short’],
  [’repeat’(1-100) or ’clear’], [’schedule’]
For cabinet 2-3 enter cabinet(2-3),[’long’ or ’short’],
  [’repeat’(1-100) or ’clear’], [’schedule’]
Error Messages
If the location identifier entered is not valid, the following message will be displayed:
Command aborted; please try later
If the command entered is in conflict with another currently executing command, then a 
message will be displayed showing the login id of the conflicting user and the conflicting 
command. The message is as follows:
’login id’:’command’ has a command conflict
test data-module
Help Messages
If the system technician presses 
HELP
 after entering "test data-module" the following 
message will be displayed:
Enter extension, [’long’ or ’short’],
  [’repeat’ (1-100) or ’clear’], [’schedule’]
Error Messages
If the extension format is invalid, the following error message would be displayed:
Extension invalid