Lucent Technologies lucent ユーザーズマニュアル

ページ / 2392
DEFINITY Enterprise Communications Server  Release 6
Maintenance for R6vs/si  
555-230-127   
Issue 1
August 1997
Maintenance Commands and Trouble-Clearing Aids 
Page 8-21
busyout tone-clock 
8
busyout tone-clock
This command places the specified tone/clock in a maintenance busy state. No 
periodic or scheduled tests are performed on the busied out object until it is 
released. When the object is maintenance busy it is deactivated (no call 
processing activity may include the busied object). Warning alarms (error type 
18) are generated on each tone clock circuit pack busied out, so that INADS can 
determine the state of the objects. The command, 
release tone-clock
reactivates the specified tone/clock.
Output
The following example is a display of the 
busyout tone-clock
 command.
Field descriptions
Maintenance Name
Type of busied out maintenance object: 
TDM-BUS
Result
Test result: Pass, Abort, Fail
Error Code
Numeric code explaining why the release failed or aborted. Refer 
to the detailed list of the codes by test number for each MO.
Action/Object
Qualifier
Qualifier Description
Permissions
Defaults
Feature
Interactions
busyout 
tone-clock
location
Physical location (
PC
)
Examples:
busyout tone-clock 01c 
busyout tone-clock 03d
init
inads
craft
1 (one)
none
Port
Tone/clock board address (cabinet-carrier)
Maintenance Name
Circuit pack name: TONE-PT, TDM-CLK, TONE-BD
 
 busyout tone-clock 1a                            SPE A
                            COMMAND RESULTS
   Port    Maintenance Name  Alt. Name   Result       Error Code
   01A     TONE-PT                       PASS
   01A     TDM-CLK                       PASS
   01A     TONE-BD                       PASS