Lucent Technologies lucent ユーザーズマニュアル

ページ / 2392
DEFINITY Enterprise Communications Server  Release 6
Maintenance for R6vs/si  
555-230-127   
Issue 1
August 1997
Maintenance Commands and Trouble-Clearing Aids 
Page 8-22
busyout trunk 
8
busyout trunk
This command places the specified installed or uninstalled trunk group or trunk 
group member in a maintenance busy state. No periodic or scheduled tests are 
performed on the busied out trunk groups or trunk group members until they are 
released. When the object is maintenance busy it is deactivated (no call 
processing activity may include the busied object). A single group member can 
be busied out by specifying the group and member number. All members in a 
trunk group can be busied out by specifying the trunk group number. Warning 
alarms (error type 18) are generated on each busied out maintenance object, so 
that INADS can access the state of the objects. The 
release trunk
 command 
reactivates the specified trunk group or group member.
NOTE:
If the user enters 
busyout trunk <group number>/
, the lowest 
port-location in the group is busied out. 
This s NOT recommended.
Output
The following example is a display of the 
busyout trunk 
command.
Alt. name
Not applicable
Result
Test result: Pass, Abort, Fail
Error Code
Numeric code explaining why the release failed or aborted. Refer to 
the detailed list of the codes by test number for each MO.
Action/Object
Qualifier
Qualifier Description
Permissions
Defaults
Feature
Interactions
busyout trunk
group
member
Trunk group number (1–99)
Number of a trunk within a trunk 
group (1 – 99)
Examples:
busyout trunk 78 
busyout trunk 78/1
init
inads
craft
none
none
 
 busyout trunk 78/1                             SPE A
                           COMMAND RESULTS
   Port    Maintenance Name  Alt. Name   Result       Error Code
   01C1505   CO-TRK           78/01       PASS
 Command successfully completed