DEFINITY Enterprise Communications Server  Release 6
Maintenance for R6vs/si  
555-230-127   
Issue 1
August 1997
Maintenance Commands and Trouble-Clearing Aids 
Page 8-28
change system-parameters maintenance 
8
Field descriptions
change system-parameters 
maintenance
This command specifies and displays scheduled maintenance operations and 
maintenance support functions. It also activates and deactivates INADS alarm 
origination during repairs. To deactivate alarm origination:
1. Make a note of the current entries in the Alarm Origination and CPE Alarm 
fields so you can restore them later.
2. Change the 
Alarm Origination to OSS Numbers
 field to “neither.”
3. Change the
 CPE Alarm Activation Leve
l field to “none.”
4. If daily scheduled maintenance must remain idle during a maintenance 
procedure, set the 
Start Time
 field to a time after the session ends. If 
daily Scheduled Maintenance is running and needs to be deactivated, set 
the 
Stop Time 
field to one minute after the current time.
Stratum:
Current synchronization stratum (3, 4)
Primary:
First choice system synchronization source (blank entry = no 
synchronization); field valid only if stratum 4 synchronization is 
specified.
Secondary:
Second choice system synchronization source (blank = no 
synchronization); valid if stratum 4 synchronization selected
Location:
Circuit pack location of all administered DS1 circuit packs (port 
network, carrier and board slot)
Name:
User-defined name for the DS1 circuit pack (blank = no user-defined 
name assigned)
Slip:
If DS1 circuit pack has slip alarm, 
y
; if not, 
n
.
Port 
Network:
Display-only field specifying the port network that supplies 
synchronization through the tone clock circuit pack (valid for stratum 3 
synchronization)
 
 change synchronization                      Page   1 of   1
              SYNCHRONIZATION PLAN
       SYNCHRONIZATION SOURCE (DS1 circuit pack location)
             Stratum: 3
        Port Network: 1