DEFINITY Enterprise Communications Server  Release 6
Maintenance for R6vs/si  
555-230-127   
Issue 1
August 1997
Maintenance Commands and Trouble-Clearing Aids 
Page 8-29
change system-parameters maintenance 
8
5. Press 
Enter
 and verify that the screen displays the message:
Command successfully completed
NOTE:
For earlier releases of system software, disable Cleared Alarm 
Notification and Restart Notification before submitting the form.
NOTE:
When finished working on the switch be sure to return all fields to 
their original settings.
Output
The following output example shows a display of the 
change 
system-parameters maintenance
 command
Action/Object
Qualifier
Qualifier Description
Permissions
Defaults
Feature
Interactions
change 
system-parameters 
maintenance
Examples:
change 
system-parameters 
maintenance
init
inads
craft
cust
rcust
none
none
change system-parameters maintenance                            Page   1 of 3
                   MAINTENANCE-RELATED SYSTEM PARAMETERS
 
OPERATIONS SUPPORT PARAMETERS
            Product Identification: 1000000000
        First OSS Telephone Number: 5551212           Abbrev Alarm Report? y
       Second OSS Telephone Number: 5551213           Abbrev Alarm Report? n
  Alarm Origination to OSS Numbers: both
        Cleared Alarm Notification? y                Suspension Threshold: 5_
              Restart Notification? y
           Test Remote Access Port? n
        CPE Alarm Activation Level: none
              Packet Bus Activated? n
     Customer Access to INADS Port? n
       Repeat Dial Interval (mins): 7
 
SCHEDULED MAINTENANCE
                  Start Time: 22: 00                    Stop Time: 04: 00
           Daily Maintenance: daily              Save Translation: daily
 Control Channel Interchange: no        System Clocks Interchange: no
             SPE Interchange: no             EXP-LINK Interchange: no