Lucent Technologies lucent ユーザーズマニュアル

ページ / 2392
DEFINITY Enterprise Communications Server  Release 6
Maintenance for R6vs/si  
555-230-127   
Issue 1
August 1997
Maintenance Commands and Trouble-Clearing Aids 
Page 8-55
display communication-interface 
8
Output for Processor-Channel Object
When you enter the command: 
display comm proc
, the systems displays 
Processor Channel Assignment screen, similar to the figure below. 
Field descriptions
Identification
This field records the type and identification number of the 
machine connected to this link. This field is for informational 
purposes only.
Proc Chan
The field identifies one of the processor channels on the 
processor link. The valid range for a processor link is 1 to 16. 
Each interface link corresponds to a port on a PGATE board. 
The Processor channel is not administered.
To specify a network channel to a remove machine, use this 
link/logical channel pair and the one specified in the interface 
link and interface channel field.
Application
This field specifies the type of application that connects to this 
processor channel. The following lists the valid entries:
Interface Link
The interface link to which the processor channel is connected.
Interface Chan
The channel on the interface link to which the processor 
channel is connected.
Local Port
The switch application port used by the local session.
 
 display communication-interface processor-channels         Page   1 of 8
 
                         PROCESSOR CHANNEL ASSIGNMENT
 
  Proc                   Interface   Local  Remote  Adjunct
  Chan   Application    Link   Chan   Port   Port    Name    Machine-ID
    1:     dcs           3      1      1      1                  13
    2:     audix         1      1      59     11    AUDIX1       1
    3:     audix         2      1      59     11    audix2       2
    4:     gateway       1      10     59     10
    5:     gateway       1      9      59     9
    6:
    7:
    8:
    9:
   10:
   11:
   12:
   13:
   14:
   15:
   16: